For several years now, our company has a background in measuring technique (measuring instruments, calibrating equipment, colleagues with metrology knowledge), which makes it possible to calibrate the measuring equipment which is used in development and production and, by means of that, to calibrate our products. Recently, a new demand arose on the part of our customers that we should supply our products with a calibration certificate.
To satisfy that demand we developed our calibration laboratory in 2003 and 2004, which is suitable for the calibration of all of our products, but we are ready to calibrate products and measuring instruments of other companies too.

Our calibration laboratory is suitable for the calibration of the following measuring instruments:


Calibration activities

The calibration of digital and analogue multimeters:
  • Measurement of direct voltage
  • Measurement of the effective value of a sinusoidal alternating voltage
  • Measurement of direct current
  • Measurement of the effective value of a sinusoidal alternatingcurrent
  • Measurement of direct-current resistance in 2 and/or 4 wire connection

The calibration of decade resistance boxes:
  • The decade with the greatest place value of the measure of the resistance that can be calibrated cannot be greater than 100MΩ, and the decade with the smallest place value cannot be less than 0,1Ω
The calibration of temperature indicators with thermocouple inputs:
  • Such temperature-indicator digital instruments, to which thermocouples of B, C , E, J, K, L, N, R, S, T types can be connected

The calibration of temperature indicators with resistance thermometer input:
  • Such temperature-indicator digital instruments, to which platinum- resistance thermometers with a nominal resistance of 100Ω and a characteristic of Pt-385 can be connected
The calibration procedure of electric power meters:
  • The calibration of electric power meters with analogue or digital displays

The calibration procedure of manometers:
  • The calibration of manometers which indicate the measured pressure directly and have a flexible sensor which has an upper measurement limit in the range of 50mbar%70bar. From the point of view of applying this procedure, the manometer is a mechanical manometer, which operates on the principle of elastic deformation of its sensor. The procedure does not apply to the calibration of manometers, which have a special way of operation like, for example, variometers, blood pressure gauge and barometers without a connecting element

The calibration procedure of pressure remote transmitters:
  • The calibration of pressure remote transmitters which have a pressure range of 0-600bar and linear characteristics with 0…20mA, 4…20mA output signals